Indirect Measurement of Blood Pressure in Neonates Using an Automatic Noninvasive Oscillometric Monitor
Jung Hea JH Park1, Hea Jin HJ Choeh1, Eun Sik ES Kang1, Chong Sung CS Chung1, Kyuchul Kc Choeh1
1Department of Pediatrics, Eulji General Hospital, Taejon, Korea
Abstract
The measurement of blood pressure in neonates is an important diagnostic procedure. But the measurement of blood pressure has not been performed routinely because of difficulty in measuring blood pressure and varable normal range according to measuring apparatus. Recently some accurate and convenient apparatus of measuring blood pressure have been introduced in neonatal care, so the reference values of neonatal blood pressure may be obtainable. The authors measured systolic and diastolic blood pressure using a noninvasive oscillometric monitor instrument on 1, 3, 6, 12, 24, 48, 72 hours of life in 200 neonates born at Eulji General Hospital, Taejon. And we analysed the results according to birth weight, gestational age, delivery type, sex, meconium stain, preeclampsia and hypocalcemia. The following results were obtained: 1) On the 1st day of life, systolic and diastolic blood pressure were 65.611.7mmHg and 36.75.8mmHg in the normal birth weight neonates, and 56.26.7mmHg and 34.14.2mmHg in the low birth weight neonates, respectively. So the blood pressure of normal birth weight neonates were higher than that of low birth weight neonates. 2) On the 1st day of life, systolic and diastolic blood pressure were 65.511.8mmHg and 36.65.8mmHg in the fullterm neonates, and 57.65.2mmHg and 35.63.8mmHg in the preterm neonates, respectively. So the blood pressure of full term neonates were higher than that of preterm neonates. 3) The difference of blood pressure in analysis according to birth weight were wider than that according to gestational age. 4) The blood pressure of neonates were lowest on the 3 hours of life and increased gradually during 72 hours of life. 5) The blood pressure of neonates did not show any significant difference in analysis according to sex. Delivery type, Meconium stain, preeclampsia, and hypocalcemia.

Keywords :Blood Pressure, Neonate, Oscillometry