Clinical and Experimental Pediatrics

Search

Search

Close


Warning: fopen(/home/virtual/pediatrics/journal/upload/ip_log/ip_log_2024-11.txt) [function.fopen]: failed to open stream: Permission denied in /home/virtual/pediatrics/journal/ip_info/view_data.php on line 93

Warning: fwrite(): supplied argument is not a valid stream resource in /home/virtual/pediatrics/journal/ip_info/view_data.php on line 94

All issues > Volume 48(8); 2005

Original Article
Korean J Pediatr. 2005;48(8):857-864. Published online August 15, 2005.
Relationship between the Body Fat Mass Measured by Bioelectrical Impedance Analysis(BIA) and Dual Energy X-ray Absorptiometry(DEXA), and by the Indices of Insulin Sensitivity
In Seok IS Lim1, Ki Wook KW Yun1
1Department of Pediatrics, College of Medicine, Chung Ang University, Seoul, Korea
Correspondence In Seok IS Lim ,Email: inseok@cau.ac.kr
Abstract
Purpose
: The objectives of this study was to evaluate the correlations between the indices of insulin sensitivity using fasting glucose and insulin level, and the body fat mass measured by bioelectrical impedance analysis(BIA) and dual energy X-ray absorptiometry(DEXA), and to determine the clinical usefulness of insulin sensitivity indices when obese children were followed up.
Methods
: In this study, 28 simple obese children and adolescents were included. Anthropometric data including body weight, height, obesity degree(OD), body mass index(BMI), and waist-to-hip ratio were collected and then body fat mass was measured by using BIA and DEXA. For metabolic data, 12 hour fasting serum glucose, insulin and lipid profiles were measured and indices for insulin sensitivity(G/I ratio, loginsulin, HOMA-IR, logHOMA-IR, QUICKI) were calculated.
Results
: BMI had a higher correlation with insulin sensitivity indices than OD(G/I ratio, -0.463 vs -0.209; loginsulin, 0.417 vs 0.196; HOMA-IR, 0.301 vs 0.238; logHOMA-IR, 0.403 vs 0.198; QUICKI, -0.451 vs -0.224). But OD had a higher correlation with body fat mass measured by BIA and DEXA than BMI(BIA, 0.612 vs 0.316; DEXA, 0.667 vs 0.512). The G/I ratio was correlated with body fat mass in BIA(r=-0.420, P<0.05) and DEXA(r=-0.512, P<0.01), percentage of body fat(percentage of fat) in BIA(r=-0.366, P<0.05) and DEXA(r=-0.449, P<0.01). HOMA-IR was only correlated with body fat mass in DEXA(r=0.341, P<0.05).
Conclusion
: This study revealed that G/I ratios had a statistically significant correlation with anthropometric obesity indices(OD and BMI) and also had a correlation with both body fat mass and percentage of fat. These results suggest that G/I ratios could be used as useful index when obese children and adolescence are followed up.

Keywords :Insulin sensitivity , Bioelectrical impedance analysis , Dual energy X-ray Absorptiometry , G/I ratio

Go to Top