All issues > Volume 67(5); 2024
Exploring the role of laryngeal masks in neonatal resuscitation
- Corresponding author: Euiseok Jung, MD, PhD. Division of Neonatology, Department of Pediatrics, Asan Medical Center Children’s Hospital, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea Email: euisjung@amc.seoul.kr
- Received September 5, 2023 Revised November 28, 2023 Accepted November 30, 2023
In neonatal care, progress is driven by an unwavering commitment to safe and effective practices. A recent study illuminated the potential of laryngeal masks (LMs) as an alternative interface for positive-pressure ventilation (PPV) during neonatal resuscitation [1]. The discussion on LMs in the most recent Textbook of Neonatal Resuscitation, 8th edition, differs from those in prior editions in which LMs were presented as alternatives in cases of challenging endotracheal intubation. The current version highlights the use of LMs during PPV [2]. Moreover, the International Liaison Committee on Resuscitation recommends employing LMs as alternative secondary airway devices for resuscitating infants older than 34 weeks of age [3]. However, as with any medical innovation, a measured and comprehensive assessment of their the advantages and potential limitations is essential prior to widespread LM adoption.
The study “Updates in neonatal resuscitation: routine use of laryngeal masks as an alternative to face masks” beckons us to examine the unique attributes of LMs within the context of neonatal care [4]. Their key advantage is the provision of a stable and less invasive airway access, which differs from conventional methods that require laryngoscopy. This novel approach may mitigate the risks associated with tracheal intubation and potentially sidestepping complications, such as esophageal intubation, cardiac arrest, endobronchial intubation, airway trauma, laryngospasm, hypotension, and compromised oxygen levels [5]. This proactivity toward risk reduction underscores the pragmatic appeal of integrating LMs into neonatal resuscitation protocols.
Furthermore, the advantages of LM insertion techniques merit consideration. The simplicity with which these techniques can be taught to less experienced healthcare providers is an asset that caters to the need for swift intervention. Equally important is the retention of skills tied to LM insertion, which surpasses those of both face mask ventilation and endotracheal intubation [6]. This attribute aligns with the demand for efficient and efficacious interventions, a crucial aspect of the intricate landscape of neonatal resuscitation.
However, as the healthcare community embraces the potential of LMs, a judicious approach entails acknowledging potential challenges. A pertinent concern revolves around the possibility of aspiration of gastric contents linked to LM use. Gastric air insufflation due to malpositioning or mask obstruction by the epiglottis can lead to gastric distension, posing a significant risk of reflux and aspiration and endangering affected infants [7]. Unlike endotracheal tubes (ETTs), LMs cannot be used for tracheal suctioning when required, prompting careful consideration in cases involving exposure to meconium-stained amniotic fluid. This limitation underscores the importance of rigorous research and exploration [3].
In addition, gastric insufflation warrants further investigation. Although second-generation LMs offer potential solutions, ongoing examinations are required [8]. These products stand out because they enable access to and effective separation of the respiratory and digestive tracts. Moreover, the incorporation of a drain tube is a convenient option for evacuating the gastric contents [9]. Studies comparing gastric insufflation across various LM models and ETTs yielded varied results, underscoring the nuanced nature of these considerations [10].
Moreover, adherence to manufacturer-recommended LM sizes is critical. Notably, the laryngeal mask airway (LMA) Classic and LMA Supreme size 1 lacked a lower weight limit but featured an upper limit of 5 kg. In contrast, the i-gel size 1 was designed for infants weighing 2–5 kg [3]. Clinical trials involving the LMA Supreme for neonatal resuscitation included infants with birth weights as low as 1.5 kg [11]. Moreover, there are reports of successful LM usage in an 800-g newborn, indicating a widening scope [12]. Furthermore, recent studies highlighted the potential applicability of LMs for administering surfactant. A pivotal randomized controlled trial evaluated surfactant delivery via the LMA in preterm infants with respiratory distress syndrome. Impressively, this study demonstrated the noninferiority of surfactant therapy via LMA, showcasing its ability to outperform the ETT approach by yielding a lower early failure rate. This favorable outcome may be attributed to the avoidance of adverse effects associated with premedication, laryngoscopy, and intubation [13]. These findings underscore the potential of LMAs to function as reliable conduits for well-controlled surfactant administration, aligning seamlessly with their pivotal roles in neonatal resuscitation protocols.
In conclusion, the integration of LMs as a conduit for PPV in neonatal resuscitation holds potential but warrants prudent consideration. This necessitates a comprehensive evaluation and careful weighing of LM advantages and complexities. As innovation progresses, a discerning approach requires an in-depth understanding of its potential benefits, plausible drawbacks, and ongoing research. The true utility of LMs for enhancing neonatal resuscitation protocols will emerge through diligent investigation and deliberate implementation.
- Footnotes
Conflicts of interest No potential conflict of interest relevant to this article was reported.
- References
- 1. Pejovic NJ, Myrnerts Hook S, Byamugisha J, Alfven T, Lubulwa C, Cavallin F, et al. A randomized trial of laryngeal mask airway in neonatal resuscitation. N Engl J Med 2020;383:2138–47.
[Article] [PubMed]2. Weiner GM, Zaichkin J. Updates for the neonatal resuscitation program and resuscitation guidelines. Neoreviews 2022;23:e238–49.
[Article] [PubMed]3. Mani S, Pinheiro JMB, Rawat M. Laryngeal masks in neonatal resuscitation-a narrative review of updates 2022. Children (Basel) 2022;9:733.
[Article] [PubMed] [PMC]4. Song ES, Jeon GW. Updates in neonatal resuscitation: routine use of laryngeal masks as an alternative to face masks. Clin Exp Pediatr 2023;Jul 11 doi: 10.3345/cep.2023.00619. [Epub].
[Article]5. Foglia EE, Ades A, Napolitano N, Leffelman J, Nadkarni V, Nishisaki A. Factors associated with adverse events during tracheal intubation in the NICU. Neonatology 2015;108:23–9.
[Article] [PubMed]6. Pejovic NJ, Trevisanuto D, Lubulwa C, Myrnerts Hook S, Cavallin F, Byamugisha J, et al. Neonatal resuscitation using a laryngeal mask airway: a randomised trial in Uganda. Arch Dis Child 2018;103:255–60.
[Article] [PubMed]7. Wahlen BM, Heinrichs W, Latorre F. Gastric insufflation pressure, air leakage and respiratory mechanics in the use of the laryngeal mask airway (LMA) in children. Paediatr Anaesth 2004;14:313–7.
[PubMed]8. Trevisanuto D, Cavallin F, Nguyen LN, Nguyen TV, Tran LD, Tran CD, et al. Supreme laryngeal mask airway versus face mask during neonatal resuscitation: a randomized controlled trial. J Pediatr 2015;167:286–91.e1.
[Article] [PubMed]9. Hosten T, Gurkan Y, Ozdamar D, Tekin M, Toker K, Solak M. A new supraglottic airway device: LMA-supreme, comparison with LMA-Proseal. Acta Anaesthesiol Scand 2009;53:852–7.
[Article] [PubMed]10. Ozden ES, Meco BC, Alanoglu Z, Alkis N. Comparison of ProSeal Laryngeal Mask Airway (PLMA) with cuffed and uncuffed endotracheal tubes in infants. Bosn J Basic Med Sci 2016;16:286–91.
[Article] [PubMed] [PMC]11. Trevisanuto D, Cavallin F, Mardegan V, Loi NN, Tien NV, Linh TD, et al. LMA Supreme for neonatal resuscitation: study protocol for a randomized controlled trial. Trials 2014;15:285.
[Article] [PubMed] [PMC]12. Brimacombe J, Gandini D. Airway rescue and drug delivery in an 800 g neonate with the laryngeal mask airway. Paediatr Anaesth 1999;9:178.
[Article]