Collection Method and Specificity Analysis of Korean HLA Anti-Body Sera. |
Jin Oh Chung1, Jong Ryur chae1, Dong Hak Shin1, Noboru Kobayashi2, Takeoh Jujh2 |
1Keimyung University School of Medicine, Taegu Presbyterian Medical Center, Department of Pediatric, Korea. 2Tokyo University, School of Medicine, Department of Pediatric, Japan. |
轉國人의 抗白血球抗體蒐集 方法과 抗血淸에 있어 抗 HLA 特異法分析(I) |
鄭鎭吾1, 蔡鍾律1, 申東鶴1, 小林登2, 字猛夫2 |
1啓明大學校 醫科大學 東山基督病院 小兒科 2東京大學 醫學部 小兒科 |
|
|
Abstract |
In order to obtain a reliable test result of the HLA detection of major histocompatibility antigen, it is very significant to get complete result by using excellent anti-sera. so far no standard sera for HLA type has been seen in Korean people. Because we have been unable to find Korean specific antigen in Korea, we have performed screening test on the 150 pregenancy women in order to find an excellent Korean anti-HLA anti-body sera. To get panel lympocyte reaction, 20 healthy Korean and 34 healthy japanese who were well aware of HLA type were given microlymphocyte toxicity test of Thrasaki method. The result showed the the 10percent of the 150 persons had anti HLA sera. Of 10 percent, 2 persons indicated having P 50. it is estimated that there are unknown A, B locus blank and antigen still seisted among many Koreans and we are ging to screen about 2,000 more persons in the future. |
|