We report a case of a full-term neonate with persistent pulmonary hypertension who developed asphyxia after birth and was treated with iloprost. The neonate had persistent hypoxia and did not respond to supportive treatment. Because inhaled nitric oxide (iNO) was not available in our hospital, inhaled iloprost was administered via an endotracheal tube. This resulted in an immediate elevation of... |