Continuous Intravenous Glucose Infusion and Serum Glucose in Neonates.
Hae June Park, Jung sik Rhim, Baek Keun Lim, Jong Soo Kim
Clin Exp Pediatr. 1987;30(5):499-503.   Published online May 31, 1987
Serum glucose changes by constant infusion of glucose at the rate of 8 mg/kg/min were studied in 20 neonates. Serum glucose level elevated from 41 ±8 mg/dl to 80 ±31 mg/dl within 10 minutes of infusion. In some cases hyperglycemia above 150 mg/dl was observed from 40 minutes of infusion. Constant glucose infusion was found to be useful for elevation of glucose level...