Search

  • HOME
  • Search
Original Article
The Effect of Phototherapy in Distance between Light Source and Hyperbilirubinemic Baby.
Jae Gye Ryoo, Hong In Eum, Kyung Tae Kim, Kew Taek Kim
Clin Exp Pediatr. 1983;26(12):1173-1178.   Published online December 31, 1983
Warshaw reported radiat flux is closely related to distance between light source and patient for phototherapy. We tried to compare 30 cm distance (group A) frome light source to patient with 80 cm (group B) for effect of phototherapy. 1) Radiant flux were 4.68±0.3㎼/cm2/nm in group A phototherapy unit ard 1.49±0. 02㎼/cm2/nm in group B...
Case Report
A Case of Collodion Baby.
Jae Gye Ryoo, Hong In Eum, Sang Cheal Lee, Jung Hee Lee
Clin Exp Pediatr. 1983;26(11):1115-1119.   Published online November 30, 1983
Ws expsrienced a ca.ss of Collodion Baby of 6 hours old female infant who was suffering from excs33ive lamellated scale, tight looking appearance and covering entire, body, typical features of parchment like skin, ectropion of upper and lower eyelids and fixed semiflexion position of the limb3. Diagnosis of Collodion Baby was established by clinical features and histopathological studies. A brief review of literature was made.
Original Article
Clinical and Follow up Study of 52 cases of Blood Exchange Transfusion for Neonatal Hyperbilirubinemia.
Hong In Eum, Jae Gae Rheu, Sang Cheol Lee, Jung Hee Lee
Clin Exp Pediatr. 1983;26(10):996-1003.   Published online October 31, 1983
The study was made of 52 cases of neonatal hyperbilirubinemia receiving blood exchange transfusion at St. Benedict Hospital from January 1977 to June 1981 with the following results; 1) 34.6% of total exchanged patients were born at St. Benedict hospital. Remains were born at outside. 2) 27 patients(51.9%) returned for follow up, 21 patients(40.4%) not returned for follow up 4 patients (7.7%) had died. 3) The...
Statistical Study for the Reasons of Artificial or Mixed Feeding and Breast Feeding.
Woo Sik Chung, Hong In Eum, Byung Do Nam, Jung Hee Lee, Kew Tae Kim
Clin Exp Pediatr. 1982;25(10):1046-1052.   Published online October 31, 1982
The survey was performed on 418 cases of mothers who were visited our pediatric out- patients and well baby clinics from January to July of 1981. The results of this survey were as follows: 1. The differentation of weight, height, chest circumference between the mothers of arti- ficial or mixed feeding and breast feeding was not seen. 2. The average nipple length of mothers of breast feeding,...